Installation

SmartLink 3 Virtual Machine

SmartLink 3 Virtual Machine contains:

  • The full version of SmartLink installed on a VMware virtual machine with Windows 7
  • The manuals and the step-by-step guide to correctly configure SmartLink and SmartPager

SmartLink 3 Installer

To install SmartLink 3 on a physical PC:

  1. Download both SmartLink Tools and SmartLink Setup
  2. Run ToolsSmartLink.exe, that will install the software needed by SmartLink to work
  3. Run SetupSmartLink.exe, that will install the full version of SmartLink

Note: the installer works on Windows only

SmartLink LiveUpdate – Version 3 – build 3002 – apk 1.8.4.7 

From here you can request to update your existing SmartLink installation to the latest version.

Click Request LiveUpdate and fill in the form with all the required information.

X-Framework

X-Framework is a Windows service that allows managing different apps concurrently.

X-Framework is only needed when installing X-Port, X-Connect, X-Adapter or SmartPanels.

To install X-Framework download X-Framework Setup, then follow the instructions to activate and manage the apps.

“SmartPanels Wall” use “Panel PC” to display alarms

SmartLink Main Alarm Station

SmartLink Main Alarm Station show Alarms and Parameter in the Wall Screen.

To install SmartLink Main Alarm Station just download and run SmartLink Setup, on the left.

Note: the installer works on Windows only

History

Changelog:

SmartPager

  • Added three sliders in SmartPager application: Beds List, Silence Room and Blue Code
    • Beds List: list of the beds with details on the bedside devices connection status for each bed
    • Silence Room: silence alarm notification for a specific room and for a specific time
    • Blue Code: generalized emergency alarm for a specific room, sent to all pagers
  • Added option for prolonged alarm notification: the pager rings until the alarm stops on the device
  • Improved User Interface
  • Bedside devices integration: data can be collected from any possible source, including BeneLink, SmartLinx, X-Connect
  • Beds information management: with connected devices list and device parameters display on real-time
  • Possible integration between SmartPager and other medical applications provided by the bedside devices’ manufacturers (current available integration: Mindray’s Mobile Viewer)

SmartLink server runs as a Windows service

Wizard
Improved wizards to simplify the SmartLink installation and configuration processes (Wizard IT / Wizard Clinical / Dashboard):

  • Wizard IT: for IT specialists. Installation and configuration of SmartLink
  • Wizard Clinical: for application specialists. Configuration of alarms, escalation rules, pager assignment
  • Dashboard: overview of the SmartLink system

Possible integration with EMR (Electronic Medical Record) and HIS (Hospital Information System)

Added EWS alarms management and compatibility up to EGW 7.1 version.

Minor bugfixes and improvements


Downloads:

Changelog:

Added compatibility with Mindray eGateway 6.4

Added compatibility with Mindray CMS 7.14
Only for installations with CMS version 7.14, it is possible to connect up to 32 monitors simultaneously (no need to make changes in SmartLink configuration).

Added compatibility with Windows Server 2016

Improved alarm escalation
A new notification is sent when an alarm stays active for a certain time after the first notification, even if a nurse took it in charge, improving the system safety.

SmartPager

  • Added compatibility with Android 7.0
  • Set minimum sound level – Possibility to define a custom minimum alarm sound level.
  • Alarm parameter showed in Alarm List – The parameter that triggered the alarm is displayed in the alarms list.
  • Filter all beds alarms or assigned beds alarms – According to the pager assignment rules set, from the alarms list screen it’s possible to toggle between “all beds” alarms and “beds assigned to me” alarms views.
  • Portrait Orientation – From the configuration options, it’s possible to set the portrait orientation (useful for example for tablets).
  • Single notification for disconnection option – It’s possible to set a single, non-repeating alarm notification for the “disconnection” alarm for when the smartphone is outside of the hospital/ward WiFi covered area. This option was developed to allow pleople on call to exit the hospital area without being annoyed by the constant alarm sound.
  • Ask confirm for Help Me and/or Take charge – It’s possible to request an action confirmation when a nurse take in charge an alarm or sends a help request.
  • Coexistence of SmartPager with other applications – It is possible for other applications to be installed and used alongside SmartPager activating the widget option. Whenever an alarm is triggered, SmartPager comes back to the foreground to alert the user.

Pager Assignment on pager

  • User and password-based identification – The pager assignment can be accessed directly from the smartphone through a user and password identification method.
  • Password changing allowed for all users on SmartPager – The user’s password can be changed by the user directly from the pager.
  • Patient name displayed in pager assignment on pager – In addition to the displayed beds to be assigned, the patient name is automatically shown to know which bed is associated to which patient.

Wizard
We developed two dedicated wizards to simplify the SmartLink installation and configuration processes:

  • Wizard Clinical – It’s composed of the steps necessary to do an advanced configuration of the alarms, pager assignment, email notifications and allows to have a configuration overview of the system. This wizard is addressed to clinical application specialists.
  • Wizard IT – It’s composed of the steps necessary to do a complete installation of SmartLink. This wizard is addressed to IT technicians.

Dashboard Report
The Dashboard Report generates more detailed reports for the different templates (e. g. Clinical, IT, etc…)

Minor bugfixes and improvements


Downloads:

Changelog:

SmartPager

  • Compatibility with Android 6.0 – Compatibility with new specification of power saving included in Android 6.0.1 or later
  • Vibration on XCover2 – Fixed issue on XCover2 that vibrates differently in random situations
  • Control of the Task Manager and Notification menu – Blocked the access in the Notification menu and in Task Manager
  • SmartPager returns to Home Page when in standby – With the phone in standby SmartPager automatically returns to the home page after a specific time period
  • Widget – Smartpager can be used as a widget on the phone
  • Help Me – Multiple Help Me requests within 3 seconds from the same user are managed as a single notification. When the Help Me is taken in charge, all the related Help Me pop-ups are closed

Pager Assignment
Pager Assignment view as grid – Pagers/Beds in Pager Assignment showed as a grid; Escalation buttons; Option where the Nurse can’t change assignment for action 2-n

Dashboard

  • Dashboard Web – Dashboard Web needs an authentication to take in charge an alarm; autorefresh can be activated by parameter (autorefresh=1)
  • Dashboard Report – Dashboard Report includes an option to receive the complete installation parameters with the Configuration template
  • Dashboard Report new features – Dashboard Report includes the statistics for the “Slide” Alarm. Statistics for the HelpMe. More information in the Configuration

SmartWaves
Authentication mode for SmartLink Web – SmartLink authentication provides flexibility to fit both simple and complex authentication scenarios

X-Framework
X-Framework environment as Windows service – X-Framework manages different devices concurrently for panels, Apoplex, pumps and so on

X-Pager
Small business medical alarms paging system – Direct acquisition and direct connection between SmartLink and Mindray monitors

X-Panels
Extend the SmartLink capabilities showing alarm messages on wall displays – X-Panels receives and displays the alarms messages using the existing SmartLink alarms classification rules, filtering, triggering and escalation strategies

iMonitor
CMS offline send an alarm until the monitor is disconnected – Fixed issue that notificates the offline until the cable of the monitor is disconnected

Minor bugfixes and improvements


Downloads:

Changelog:

Alarms Forwarding
Multi alarms management – For each department a specific configuration can be defined for alarms to use, with four different severity levels (Critical-Serious-Generic-Technical), and for alarms persistence

SmartPager

  • NEWS – NEWS score from eGateway 6 is managed
  • Assignment on pager – Pager Assignment function directly from the pager. This feature can be useful in specific situations (e.g. the ICU ward) where there’s the need to directly assign the patients beds from the smartphone

Dashboard

  • Dashboard Agent application – DashBoardAgent allows to receive system alarms notification on Windows
  • Dashboard Report application – DashBoardReport allow to prepare different reports for different users, customizable templates, mailing lists, user interface to extract data of a specific period of time
  • Connection refused – Apollo Apache broker gets an exception to connect to the port. The memory access has been fixed (this alarm change from critical to warning)
  • Dashboard notification for statistics – For statistics purposes, the DashBoard notifications not sent to the pagers can be saved in the Alarms List

eGateway

  • Complete compatibility with eGateway 6.0 – SmartLink uses the eGateway 6.0 frame to receive alarms
  • Complete compatibility with eGateway 5.x – If eGateway 5.x is present, SmartLink uses the previous format to receive alarms
  • Real Time – SmartPager manages the RealTime parameter values display for all the received alarms
  • Parameters shown in the real time view – The parameters chosen to be displayed in the Real Time view can now be changed (selection in the configuration menu)
  • Communication security – SmartLink checks the status of the alarm channel port and, in case of failure, sends a “lost communication” system alarm message to the Dashboard
  • TM80 telemetries supported – TM80 telemetries are supported, including Nurse Calls and Event Calls

iMonitor

  • T1 pulled from T8 managed – Fixed some WiFi issues
  • Name rules on department management – Deparment name is managed by using rules like SQL (B* *B B?B B*B)

Web interface functions
ECG channel – The ECG waveforms are now shown on any monitor that is set as lead monitor

Minor bugfixes and improvements


Downloads:

Changelog:

Distributed Alarm System regulations

  • Compliance with 60601-1-8 standard (Distributed Alarm Systems)
  • Compliance with 80001-2-5 standard (Distributed Alarm Systems classification)

SmartAlarm

  • Unknown alarms management with database update
  • Unknown alarm sources management
  • Multi channel alarm forwarding using pagers, messaging systems, email, SMS
  • Nurse calls management from telemetry systems
  • Event alarm notification for telemetry systems
  • Patient monitor disconnection management

SmartConfig
Allows the configuration of SmartLink

SmartPager

  • Help me message with take in charge answer
  • Full communication chain control with operator awareness
  • Dual mode communication (double IP address)
  • Battery charge control with Dashboard messages
  • Alarm status display
  • Device assignment functions with operator identification
  • “Zero technical delay” alarms forwarding (fast message delivery)

SmartReport

  • Modal value in Pulse and SpO2 – In Pulse Rate table and in Desaturation parameters table the modal value is shown
  • More statistic informations – In SpO2 table the time spent with SpO2 less than XX% is shown
  • SpO2 Percentage table – Each row refers to the sum of values smaller of a set percentage
  • PR SpO2 – It is possible to receive PR from SpO2

SmartTrend
Update of patients’ information on the trend – If the patients’ information are not inserted at the moment of the admission, it is possible to insert them at a later stage. The information inserted later will be updated on the trend and will then be possible to search for them using filters

SmartWaves

  • Patients’ information editable for initially unknown patients
  • Pulse rate and Heart Rate automatic management
  • Centralized patient search and data retrieval for multi-ward installations
  • Alarms list print button in SmartAlarm

Dashboard

  • Full-featured dashboard for system operation control
  • Extended Dashboard user interface
  • Dashboard messages to paging devices
  • Dashboard messages using SMS
  • Dashboard messages using email
  • Dashboard Windows client (messages pop-up system)
  • Continuous timeline events control
  • Alarms tracking
  • System alarms notification through the Dashboard

Configuration and protection

  • Time from a time server – Sincronize with the timezone
  • Wizard for Internet Explorer installation client – Setup to install the client in few steps
  • Configuration check advanced functions – Wizard functions integrated in configuration
  • Simplified configuration – Few steps to install and manage the configuration, with import of alarms list from Excel file
  • Pre-installed on virtual machine – SmartLink EL is pre-installed in a virtual machine
  • English prompts and messages always available for maintenance on pagers – All messages are in your language (see manual for supported languages) and English
  • DeviceLock server protection – Provides network administrators the ability to set and enforce contextual policies
  • KNOX smartphones protection – KNOX Express to manage two profiles: SmartPager and Open
  • Hidden server application (“protected mode” server operation) – SmartLink server starts hidden when in protected mode
  • Configurable configuration steps (for different user levels) – Configuration steps organized for different user levels
  • After restart of the monitor SmartLink also needs to be restarted – Fixed

Alarms forwarding through Ascom Integration
Status of the message from Ascom (delivered, acknowledged)

Alarms forwarding through ESPA devices
ESPA-X messages sending to host ESPA-X systems

iMonitor

  • Automatic input of unknown alarms in the alarms list – When SmartLink receives alarms not present in the database, it automatically inserts them in the list and notify the action in SmartConfig, so that the new alarm can be used afterwards
  • Automatic alignment of modules, parameters and waveforms with the monitors – When SmartLink receives new unknown modules, parameters or waveforms, it automatically inserts them in the database using all the information already received from the HL7 protocol. Through SmartConfig is then possible to check the new parameters
  • Faster alarms notifications – A new technology allows to receive the alarms almost immediately, just after a couple of milliseconds since the monitor triggers the alarm
  • Nurse call managed as an alarm – From the telemetry, the nurse call is recognized as an actual alarm and sent to the PABX. This alarm is present among the alarm codes list
  • Automatic management of the SpO2 Pulse Rate – If the ECG module is missing, SmartLink is able to extract the HR value from the SpO2 module

Minor bugfixes and improvements


Downloads:

Form

The SmartLink Installation Form is a document that sums up all the information regarding a SmartLink installation.

Notes:

  • The document is an editable pdf file, meaning that it has pre-determined fields to be filled in with the installation information.
  • The document shall be filled in with information provided by the distributor representative and by the customer (IT staff, bioengineering staff, clinical staff).
  • To guarantee the highest technical support quality for the customer, send us back the filled in document and keep a copy for yourself.

Remember:

  • The document name has to be changed replacing “HospitalName” with the name of the healthcare facility.
  • After you have filled in the document, re-export the document in pdf to save the changes.

If you need support while filling in this document or while re-examining a past SmartLink installation please contact us at support@swt.it